LEVELNIC DL-m5/DL-m5W
Product details:
LEVELNIC DL-m5/DL-m5W
Lowest height in the m series of 56mm.
Able to be used for both outputting measured values by PC and by main unit.
 
High precision Digital Level
0.01mm/m display
 
Switchable Type : Wireless use / Cable use DL-m5W
 
USE
High precision leveling of machine tools and surface plates,
straightness and flatness measurement
 
MATERIAL
● Case:Aluminum
● Base: Cast Iron
FEATURES
Lowest height 56mm type in the m series
With RS-232C output for straightness and flatness software use
Jig fixing screw holes and dimensions are as same as DL-S3 and DL-S4W.
Standard equipped wireless system. Wireless and cable output to be chosen.(DL-m5W)
 
 
SPECIFICATIONS
Model Name DL-m5 DL-m5W(built-in wireless)
Measuring Range ±5.00 mm/m
Minimum Reading 0.01 mm/m
Operating Temperature 0~40℃
Accuracy*1 Operating temperature 17~23C ± 0.02mm/m or ± 3% rdg whichever is greater (0 ~± 1.99mm/m)
±4% rdg(± 2~±5mm/m)
Operating temperature 0 ~40C± 0.02mm/m or ± 5% rdg whichever is greater (0 ~±1.99mm/m)
±6%rdg(±2~±5mm/m)
Repeatability Within ±0.01mm/m
Measurement Interval Approx.0.5~ 0.6 sec.
Output Signal Wired RS-232C*4 Built-in wireless
(Bluetooth Class1*3,Communication distance: 30 ~ 50m)
Wired RS-232C*4
Power Source AA battery x 2
Run Time Zinc-carbon battery Approx. 100 hrs. (approx. 50 hrs. With signal output)
Akaline battery Approx. 200 hrs. (approx. 100 hrs. with signal output)
Zinc-carbon battery Approx.50 hrs.(approx.30 hrs.with cable output)
(approx.8 hrs.with wireless output)
Alkaline battery Approx.100hrs.
(approx.70 hrs.with cable output)
(approx.20 hrs. with wireless output)
(continuous use)*2 L155 X W50 X H56mm
(base: L150 X W5Omm)
Dimensions Carrying case
Warranty· Instruction manual· Inspection report
AA battery x 2
● Wireless receiver unit for PC(RS-232C) *4
Carrying case
Warranty . Instruction manual . Inspection report
AA battery x 2
※1 :%rdg (percent reading) indicates percentage of the reading.
土3% rdg can contain an error of土0.03mm/m if the reading is 1.00mm/m.
※2 : May vary depending on usage conditions such as temperature.
※3: Our Bluetooth system qualification is with TELEC (Japan), FCC (U.S.A), CE (EU) and KCC (South Korea).
※4: PC without D-SUB9 pin port (RS-232C) requires USB serial transmitter (optional) .
Copyright © Wyldar Machine Tool Ltd. All rights Reserved
Headquarters in Hong Kong: Wyldar Machine Tool Ltd. Tel: 852-24899881 Fax: 852-24804721
Service headquarters in Jiangmen: Jiangmen Jingda Electromachanical Co, Ltd. Tel: 0750-3860864 Fax: 0750-3860866