Features of the Point Finder Series

  • High precision 3D touch sensor (probe) 'Point Finder series' is enable to do any kind of measurements such as reference position, inside/outside diameters, centering, angle, groove width, and height.
    For the ultrahigh-precision 3D touch sensor → 【Centering Gauge Swing Type】
  • Safety design enables the stylus swing toward X, Y and Z-axes directions and prevents the Point Finder itself from breakage.
  • Four LEDs light up when the stylus touches to a workpiece.
  • As for PTC (Point finder with a buzzer), three LEDs light up and the buzzer let you know when the stylus touches to a workpiece.
  • With nonmagnetic stylus, magnetic force doesn't affect to the measuring.
    → Check the details of 【Nonmagnetic Stylus】
  • Water-proof Point Finder meets IP67, which is the standard cord to show the degree of protection against dust or water by International Electrotechnical Commission, so it can be used at the factory where the Point Finder would get wet by cutting fluid and be exposed to dust.
Point Finder
[External Contact Type]
  Point Finder-i
[Internal Contact Type]
iron, nonferrous metal Measurable material metal, nonmetal (plastic, wood...)
XY-axes ±11.5mm Stylus stroke XY-axes ±6mm
Z-axis +5mm Z-axis +5mm
±0.5μm
(±1μm with the 80mm stylus)
Repeatability (*1) ±0.5μm
XY-axes 0.001N Measuring pressure XY-axes 0.3N
Z-axis 0.001N Z-axis 1.5N
φ1、φ2、φ3、φ4、φ5、φ6 Stylus tip diameter φ2、φ3、φ6
ST-6×40NM(*2) Standard stylus ST-6×29NM(*2)
PTC series has a buzzer Other feature available to MC with a ceramic spindle

*1:'Repeatability' is a level to show the repeat accuracy of the standard stylus
   when it returns to the original position.
*2:You can change the size of stylus instead of the standard one.
   For details, refer to 【Nonmagnetic Stylus】

How to Measure

Point Finder series are available to measure any position and angle.

 Point Finder makes it possible to do any kind of measurements such as reference position, inside/outside diameters, centering, angle, groove width, and height. Those measurements are very important before metal working.

 With a point finder, it is easy to measure the angle of narrow workpieces, which angle gauges can't measure, on the machining center.

point finder makes it easy to measure angle of a workpiece.


Specifications of the Point Finder series

Use model 'PTN' and 'PTC' when a workpiece is metal or nonferrous metal.
'SPi' is used for measuring plastic, wood and some other materials which block electricity.
For small high-speed mashining center, 'Type 06' is available.

Point Finder
[External Contact Type]
Point Finder-i
[Internal Contact Type]
Model Shank Note / Included battery Model Shank Note / Included battery
PTN-06N φ6 A magnet cable is
included. / 2 silver oxide
batteries [SR-44]
SPi-06 φ6 2 silver oxide batteries
[SR-44]
PTN-10 φ10 1 lithium battery [BR-435] SPi-10 φ10 1 lithium battery [BR-435]
PTN-20 φ20 2 alkaline batteries [LR1AG] SPi-20 φ20 2 alkaline batteries [LR1AG]
PTN-25 φ25 SPi-25 φ25
PTN-32 φ32 SPi-32 φ32
PTC-20 φ20 with buzzer /
2 alkaline batteries [LR1AG]
BT30-SPi BT30 2 silver oxide batteries
[SR-44]
PTC-32 φ32 BT40-SPi BT40
PTN-E32 HSKφ32 2 silver oxide batteries
[SR-44]
SPi-E32 HSKφ32

*In place of alkaline batteries [LR1AG], manganese cells can be used.
**As a standard-sized stylus, ST-3×23.5NM is equipped with a small point finder (PTN-06N, SPi-06),
  ST-6×40NM with a point finder, and ST-6×29NM with a point finder-i.
  It is possible to exchange the size of stylus. For details, refer to 【Nonmagnetic Stylus】.

'Water-proof Point Finder Series' have a structure to prevent cutting fluid and invisible dust from entering inside of sensor.
It meets IP67, IEC standard. Eliminate measurement error, and get high machining quality with it!

Water-proof Point Finder
[External Contact Type]
Water-proof Point Finder-i
[Internal Contact Type]
Model Shank Note / Included battery Model Shank Note / Included battery
S10WP φ10 1 lithium battery [BR-435] S10WPi φ10 1 lithium battery [BR-435]
S20WP φ20 2 alkarine batteries [LR1AG] S20WPi φ20 2 alkarine batteries [LR1AG]
S32WP φ32 S32WPi φ32
BT30WP BT30 2 silver oxide batteries
[SR-44]
BT30-WPi BT30 2 silver oxide batteries
[SR-44]
BT40WP BT40 BT40-WPi BT40

*In place of alkaline batteries [LR1AG], manganese cells can be used.
**As a standard-sized stylus, ST-6×40NM is equipped with point finder,
  ST-6×29NM with point finder-i.
  It is possible to exchange the size of stylus. For details, refer to 【Nonmagnetic Stylus】.

Using the Point Finder [External Contact Type] on a machining center with a ceramic bearing, it blocks electricity and workpiece can't be measured.
'Magnet Cable M-500' is a MUST! Length: 50cm
It's easy to use: Put a magnet on the housing (front cover) of a point finder and the other on workpiece.

A magnet cable is included with a small-size point finder, PTN-06N.
In case you buy other Point Finder [External] series, make sure the specification of the machining center you use.

Dimensions

Dimensions of Point Finder

Copyright © Wyldar Machine Tool Ltd. All rights Reserved
Headquarters in Hong Kong: Wyldar Machine Tool Ltd. Tel: 852-24899881 Fax: 852-24804721
Service headquarters in Jiangmen: Jiangmen Jingda Electromachanical Co, Ltd. Tel: 0750-3860864 Fax: 0750-3860866
[Manage]